Transport And Storage Of Cordless Tools - Hilti SJT 6-A22 Manual Del Usuario

Ocultar thumbs Ver también para SJT 6-A22:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
10

Transport and storage of cordless tools

Transport
CAUTION
Accidental starting during transport !
▶ Always transport your products with the batteries removed!
▶ Remove the battery.
▶ Never transport batteries in bulk form (loose, unprotected).
▶ Check the tool and batteries for damage before use after long periods of transport.
Storage
CAUTION
Accidental damage caused by defective or leaking batteries !
▶ Always store your products with the batteries removed!
▶ Store the tool and batteries in a place that is as cool and dry as possible.
▶ Never store batteries in direct sunlight, on heating units or behind a window pane.
▶ Store the tool and batteries in a place where they cannot be accessed by children or unauthorized
persons.
▶ Check the tool and batteries for damage before use after long periods of storage.
11
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
Trouble or fault
The saw blade drops out.
The saw blade cannot be
inserted.
The orbital action cannot be
adjusted.
The orbital action doesn't
work.
The battery runs down more
quickly than usual.
The battery doesn't engage
with an audible click.
1 LED blinks.
The power tool doesn't run.
All 4 LEDs blink.
The power tool doesn't run.
*2150255*
Possible cause
The saw blade is not correctly en-
gaged.
The clamping system is clogged
with foreign matter.
The clamping system is clogged
with foreign matter.
Foreign matter in the orbital-action
adjusting lever groove.
The orbital-action mechanism is
clogged with foreign matter.
The orbital-action adjusting lever is
in position "0".
Very low ambient temperature.
The retaining lugs on the battery
are dirty.
Low battery.
The battery is too hot or too cold.
The tool has been overloaded.
2150255
Action to be taken
▶ Repeat the insertion procedure.
▶ Make sure that the blade holder
is fully open and that the saw
blade is pushed all the way in
against the spring resistance.
▶ Clean out the blade holder.
▶ Clean out the blade holder.
▶ Clean out the orbital-action
adjusting lever groove.
▶ Check whether foreign matter
is present in the area of the
orbital-action fork and clean it
out.
▶ Adjust it to the desired setting.
▶ Allow the battery to warm up
slowly to room temperature.
▶ Clean the retaining lugs and refit
the battery.
▶ Change the battery and charge
the empty battery.
▶ Allow the battery to cool down
or warm up slowly to room
temperature.
▶ Release the on/off switch and
then press it again. Then allow
the power tool to run under no
load for approx. 30 seconds.
English
23

Publicidad

Tabla de contenido
loading

Tabla de contenido