5 Operation
5.4.5
Service/diagnostics level display
Testing of the actuators and sensors should be carried
out by an expert technician.
You can access the service/diagnostics level by pressing
the programming button P and the dial simultaneously
for at least three seconds. All the actuators and sensors
can be activated and tested in this level (see Installation
manual, Chapter 7).
The display reverts to the main operating level when you
press the programming button.
5.4.6
Installer level display
The parameters in the installer level should only be set
by an expert technician.
You can access the installer level by pressing program-
ming button P for at least three seconds.
To return to the basic display, press the programming
button briefly.
5.5
Settings
5.5.1
Calling up settings and operating values
You can call up the set values consecutively by pressing
the info button several times.
The information called up in each case is visible in the
display for approximately five seconds, after which the
display reverts to the main operating level.
Display
Settings
Cylinder temperature target value
Yield
Temperature of cylinder sensor 1
Temperature of cylinder sensor 2
Temperature of cylinder sensor 3 (if con-
nected)
Table 5.1 Settings and operating values
10
Display
Settings
Temperature of collector sensor 1
Temperature of collector sensor 2 (if con-
nected)
Operating hours for solar pump 1
Operating hours for solar pump 2
Timer programme for heating window
Table 5.1 Settings and operating values (cont.)
Further timer programmes will be displayed here, de-
pending on how many you have set (see Sections 5.5.3
and 5.5.4).
5.5.2
Settings in the main operating level
In the main operating level you can set:
– Cylinder temperature target value
– Operating mode
– Current day of the week
– Current time of day
The setting called up in each case can be viewed and set
in the display for approximately five seconds, after
which the display reverts to the basic display of the
main operating level. Click the dial before the five sec-
onds have expired to access the next setting.
Operating Manual auroMATIC 560 0020060907_00