6.0 - MANUALLY OPERATED METERING PUMP EXACTUS MA/AD SERIES
Flow can be controlled manually by setting the pump pulse rate by means of a potentiometer. Possibility of a more
precise flow rate setting at low frequencies through the two keys 20% and 100%.
6.1 - PUMP CONTROLS (Fig.12)
1 - Switch off button "STOP"
2 - 100% flow scale read out button
3 - Switch on button "START"
4 - Level alarm LED "yellow" (only for EXACTUS with level alarm, MA/ADL SERIES)
5 - 100% flow scale read out LED "green"
6 - 20% flow scale read out LED "green"
7 - Pulse LED "red"
8 - Power LED "green"
9 - 20% flow scale read out button
10 - Adjustment knob of Injections/min numbers (0÷100% max flow)
6.2 - TYPICAL INSTALLATION (Fig.13)
A
Injection valve
B
Power supply
C Filter
I
Chemical tank
S Process tank

6.3 - ACCESSORIES

1 flexible PVC suction hose,