tau K892M Guía Para La Instalación página 16

Ocultar thumbs Ver también para K892M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SOFTWARE Version 1.05 ÷ 3.00 - Table 1
Software version 1.05 includes the option to set the duration of deceleration and sensitivity of the
"obstacle detection" function, made possible by means of an encoder (optional). These functions can
be enabled by means of dipswitches 4 and 8 and are settable by means of the trimmers on the board,
as shown in table 1.
DIP 4 DIP 8
OFF
OFF
Optional LS (limit switches)
ON
OFF
Optional LS (limit switches)
Adjustable time deceleration
ON
ON
LS (limit switches) required
SOFTWARE Version 3.10 onwards - Table 2
DIP 4 DIP 8
OFF
OFF
Optional LS (limit switches)
OFF
ON
LS (limit switches) required
Deceleration with settable
time. Work time and decelera-
tion established by the SETUP
ON
OFF
Optional LS (limit switches)
Deceleration with settable
time. Work time and decelera-
tion established by the SETUP
ON
ON
LS (limit switches) required
433.92 MHz BUILT-IN RADIO RECEIVER
The radio receiver can learn up to a maximum of 8 dip-switches (TXD2, TXD4, BUG2, BUG4) or roll-
ing codes (BUG2R, BUG4R) which can be set on the two channels as required.
The first channel directly commands the control board for opening the automatic device; the second
channel commands a relay for a N.O. no-voltage output contact (terminals 9 and 10, max. 24 Vac, 1
A).
The learning mode (dip-switch or rolling code) is determined by the first radio control device and re-
mains unchanged until all the codes have been cancelled.
LEARNING SYSTEM FOR RADIO CONTROL DEVICES
P1 = OPEN/CLOSE
P2 = 2nd channel
1_ press button P1 briefly to associate a radio control device with the OPEN/CLOSE function;
2_ LED DL7 turns off to indicate that the code learning mode has been activated (if no code is en-
tered within 10 seconds, the board exits the programming mode);
16
Set mode
No deceleration
No ENCODER
Fixed time deceleration
(1/3 of TL)
No ENCODER
(TL set at 48 sec)
ENCODER required
Set mode
No deceleration
No ENCODER
No deceleration
ENCODER necessary
procedure
No ENCODER
procedure
ENCODER necessary
TM1
Automatic
closure
time
Automatic
closure
time
Automatic
closure
time
TM1
Automatic
closure
time
Automatic
closure
time
Automatic
closure
time
Automatic
closure
time
K892M
TM2
Work time
Not used
Work time
Not used
Deceleration
Encoder
time
sensitivity
TM2
Work time
Not used
Encoder
Work time
sensitivity
Not used
Not used
Encoder
Not used
sensitivity
TM3
TM3

Publicidad

Tabla de contenido
loading