O p e r a t i o n
A c t i v a t i n g / d e a c t i v a t i n g m a g n e t i c c l a m p
Sw i t c h i n g m a c h i n e O N/ O F F
CS Unitec, Inc. • Phone: 203-853-9522 • Toll-free: 800-700-5919 • Email: info@csunitec.com
M A B 4 8 5
A c t i v a t i n g m a g n e t i c c l a m p
CAUTION
►
Switch on the magnetic clamp only when the machine is
standing on a magnetic substrate to avoid overheating of the
magnet .
Turn on switch (22) . The indicator light in switch (22) comes
on .
Check the magnet clamping force at the magnet
indicator (24). When the magnet clamping force is sufficient,
the MAGNET POWER indicator light (24) is green . If the
MAGNET POWER indicator light (24) is red, there is not
sufficient magnet clamping force available.
CAUTION
►
The maximum magnet clamping force is only available after
switching on the motor .
D e a c t i v a t i n g m a g n e t i c c l a m p
Secure the machine at the handle to prevent the machine
from slipping off the surface .
Turn off switch (22) . The indicator light in switch (22) goes
out .
Turn the machine ON at the ON/OFF switch (21) with the
green button (I) and OFF with the red button (O) .
NOTE
►
The machine can only be switched on when the magnetic
clamp has been switched on .
►
Allow a severely overheated machine to run on at no-load
speed for approx. 2 minutes to let it cool down.
►
The machine switches off automatically in the event of a
power failure or if the magnetic clamp is switched off .
www.csunitec.com
O p e r a t i o n
2 1