Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18

English

! The appliance must be installed by a qualified person
GB
in compliance with the instructions provided.
!
Wear gloves when carrying out installation and
maintenance operations.
AIR VENT
(for ducting versions)
! Prepare the hole and the air vent duct (150 mm
diameter).
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible
(maximum elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! Use a duct with an as smooth as possible inside.
! The duct must be made of certified material.
! Do not connect the hood to smoke exhaust ducts for
the products of combustion (boilers, fireplaces,
stoves, etc).
! For the air vents comply with the provisions laid
down by the competent authorities.
In addition, the air must not be evacuated through a
hole in the wall unless specifically intended for this
purpose.
! Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the
same time as non-electrical equipment (gas-, oil- and
charcoal-fired stoves, etc.) the exhaust gas may be
sucked in by the heat source.
FILTERING OR DUCTING VERSION ?
The hood may be in filtering or in ducting version.
Decide from the outset which type is to be installed.
For better efficiency, we recommend installing the
hood in the ducting version (if possible).
Ducting version
The hood purifies the air and evacuates it to the
outside through an exhaust duct (diameter 150 mm).
Filtering version
The hood purifies the air and recycles the clean air
back into the room.
12
CONTROLS
P1
P3
P5
P2
P1: 5' TIMER
P2: Filter alarm reset
P3: Motor off / speed decrease – .
- holding down the button, the motor turns off
storing the current speed
P4: Motor on / speed increase
P5: Lights on/off
L1 Signalling crown:
-
Hood in standby: lights up amber-orange. 30"
after the last key has been pressed the crown
turns off
-
Motor on: L1 lights up turquoise flashing. The
flashing frequency is proportional to the speed
5' TIMER function : L1 lights up turquoise fixed
-
Filter alarm active: L1 lights up red fixed (30h);
-
L2 lights up red flashing (120h)
MAINTENANCE
! Before cleaning or maintenance cut the power.
Cleaning the hood
WHEN TO CLEAN IT: clean it at least every 2 months
to prevent the risk of fire.
EXTERNAL CLEANING: use a cloth moistened in
lukewarm water and neutral detergent (for painted
hoods); use specific products for steel, copper or brass
hoods.
INTERNAL CLEANING: use a cloth (or brush) soaked
in denatured ethyl alcohol.
WHAT NOT TO DO: do not use abrasive or corrosive
products (e.g. metal sponges, brushes, too hard
brushes, very aggressive detergents, etc.)
Cleaning the grease filters
WHEN TO CLEAN IT: clean it at least every 2 months
to prevent the risk of fire.
P4
L1

Publicidad

Tabla de contenido
loading

Tabla de contenido