INSTALLATIONINSTRUCTIONS
VENTING THE DRYER
(cont.)
DuCtwork
0
65 ft. (19.8 m)
45 ft. (13.7 m)
Recommended
1
55 ft. (16.8 m)
35 ft. (10.7 m)
_
2
47 ft. (13.7 m)
30 ft. (9.1 m)
3
36 ft. (11.0 m)
25 ft. (7.6 m)
/_02om/
/_02_m/
4
28 ft. (8.5 m)
20 ft. (6.1 m)
Use Only for Short
0
55 ft. (16.8 m)
35 ft. (10.7 m)
Run Installations
1
47 ft. (13.7 m)
27 ft. (8.1 m)
2
41 ft. (12.5 m)
21 ft. (6.4 m)
3
30 ft. (9.1 m)
17 ft. (5.2 m)
/63s_m/
4
22 ft. (6.7 m)
15 ft. (4.5 m)
.j
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended
to use more than four 90 ° elbows.
Routing and Connecting
Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation
in the ductwork.
NOTE: Ductwork and fittings are NOT included
and must be purchased separately.
• Use 4-in. (10 cm) diameter rigid or semirigid
metal ductwork.
• The exhaust duct run should be as short as
possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct
must point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated
areas in order to reduce condensation
and lint
buildup on duct surfaces.
IMPORTANT: Failure to exhaust the dryer
correctly will void the dryer's warranty.
Correct
Venting
oI
I
ii
ii
Incorrect Venting