FLOW CHECK (DUCT CONDITION TEST)
[I]'dl[n]_l
[l']i]Ivd'-.] I :I i :II] _I[i}vivi
[_11=_',4
IPI=I=II] I=ll[ilr+vl_ I I=_',q
0
24
Your dryer features FlowCheck
TM,
an innovative
sensing system that automatically
detects
blockages and restrictions in dryer ductwork.
Keeping ductwork clean of lint buildup and free
of restrictions allows clothes to dry faster and
reduces energy use.
NOTE: When the dryer is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during normal
operation provides more accurate information on
the condition of the exhaust duct than does the
installation test, the number of bars displayed
during the two tests may not be the same.
To activate the flow check (Duct condition test) :
NOTE: Dryer heating test must be performed
before proceeding. Then perform the duct
condition test below:
O
Press the OPTION button, then select
CUSTOM PGM.
@
After 3 seconds, or
by pressing the EXIT
button, the display
will show the FLOW
CHECK start screen.
FL0W CHECK [_;"% 0:0211
THISTEST CHECKS THECONDITION I
OFTHEEXHAUST DUCTATTHETIME I
OFINSTALLATION
|
Press START/PAUSE. The dryer
will run for approximately 2
minutes to test
|
for blockages or
_I
restrictions to air flow in the
FLOWCHECK
I
ductwork .......
.... I---I .... I
THE DUCTWORK IS FREE
FROM BLOCKAGES OR
RESTRICTIONS.
If no bars are shown in
the display, the ductwork
is free from blockages
or restrictions.
THE DUCTWORK HAS
A BLOCKAGE THAT NEEDS
TO BE REMOVED
IMMEDIATELY.
If all bars are lit, the
dryer ductwork has a
blockage that needs to
be removed immediately.
IMPORTANT: Do NOT interrupt the test cycle!
JCorrect
Venting
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows
or bends.
,
Check for blockages and lint buildup.
m
I
Make sure the ductwork
is not crushed
or restricted.