10 Faults, causes and remedies

Have faults remedied by qualified personnel
only! Observe the safety instructions in the
Safety chapter.
Fig. 7: Error acknowledgement sequence

10.2 History memory for the faults

A history memory has been set up for the switch-
gear and operates according to the FIFO principle
(first-IN, first-OUT). The memory is configured for
16 faults.
Code
Error description
E40
Sensor faulty
E60
Maximum pressure
exceeded
E61
Pressure below mini-
mum value
E62
Low water
E80.1 – E80.4
Fault pumps 1...4
E82
Fault frequency con-
verter
If the fault cannot be remedied, please contact
your nearest Salmson customer service point or
representative.
Installation and starting instructions Smart Control

10.1 Fault display and acknowledgement

Causes
Pressure sensor defective
No electrical connection to the sensor Repair electrical connection
The output pressure of the system
has risen above the value set in menu
5.4.1.0 (e.g. due to a controller fault)
The output pressure of the system
has dropped below the value set in
menu 5.4.2.0 (e.g. due to a pipe burst)
Protection against low water level has
tripped
Winding overtemperature (WSK/ PTC) Clean cooling fins; motors are
Motor protection has tripped (over-
current or short-circuit in the supply
line)
Collective fault signal of the pump/
frequency converter has been acti-
vated (only SCe version)
Frequency converter has signalled a
fault
Motor protection of frequency con-
verter has tripped (e.g. short-circuit
of FC mains power cable; overload of
the connected pump)

11 Spare parts

If a fault occurs, the red fault signal LED lights up,
the collective fault signal is activated and the fault
is displayed on the LCD (fault code number).
A faulty pump is indicated on the main screen by
a flashing status symbol for the corresponding
pump.
The fault can be acknowledged in menu 6.1.0.0 by
the following operation:
The error memory can be called up using menus
6.1.0.1 – 6.1.1.6.
Remedy
Renew sensor
Check controller function
Check installation
Check whether the set value corre-
sponds to local conditions
Check pipe and repair if necessary
Check inlet/preliminary tank; pumps
restart automatically
designed for an ambient temperature
of +40 °C (see also installation and
operating instructions of the pump)
Check the pump and supply line (in
accordance with the installation and
operating instructions of the pump)
Check the pump and supply line (in
accordance with the installation and
operating instructions of the pump)
Read off fault on frequency converter
and act in accordance with FC oper-
ating instructions
Check mains power cable and repair it
if necessary; check pump (in accord-
ance with the installation and operat-
ing instructions of the pump)
Spare parts are ordered via local specialist retailers
and/or Salmson customer service. To avoid que-
ries and incorrect orders, all data of the rating
plate should be submitted for each order.