After Usage; Care And Maintenance - MESTO RESISTENT PLUS Instrucciones De Uso

Ocultar thumbs Ver también para RESISTENT PLUS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GB
IRL
2. Make certain the optimum spraying pressure is set (→ Table 2) on the pressure
gauge [11].
Spraying
pressure
1.5 bar
2.0 bar
3.0 bar
Table 4. Linear relationship of: spraying rate and spraying pressure
3. If the spraying pressure decreases more than 0.5 bar from the optimum level, pump
some more.
If liquid mixed with air emerges from the nozzle, the tank is empty.

After Usage

Observe the instructions in the section entitled "Safety".
1. Pull up the red button on the safety valve [9] until all excess pressure is released from
the tank. (Fig. 3)
2. Lock the pump handle in place [10]. (Fig. 4)
3. Unscrew the pump [1] from the tank [4]. (Fig. 6)
Collect and dispose of the residual liquid according to all applicable laws,
requirements and regulations. Observe the instructions of the spray product
manufacturer!
4. Wipe off the device with a moist cloth.
5. For drying and storing the device, keep the tank and pump separate in a dry place
protected from sunlight and freezing temperatures.
Clean the protective equipment and yourself every time after usage.

Care and maintenance

Observe the instructions in the section entitled "Safety".
After using the device 50 times or at least once a year:
• Disassemble the pump [1] and grease the diaphragm [13]. (Figs. 11 - 12)
• Clean the nozzle [14] and insert [15] under flowing water. If necessary, use a needle.
(Fig. 13)
• Take the filter [16] out of the shut-off valve [6] and clean it under running water. (Fig. 14)
• Grease the O-ring [12]. (Fig. 12)
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals.
If there are no special rules, we recommend you have the device examined
externally by a competent professional every 2 years and subject it to an internal
inspection every 5 years.
We would be happy to provide you with an inspection schedule in German or
English.
AUS
Spraying quantity with nozzle 1302
0.49 l/min
0.56 l/min
0.69 l/min
USA
NZ
15
CDN
IND

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3594

Tabla de contenido