After Usage

Follow the instructions in the section entitled „Safety".
Never leave spraying agent in the device.
1. Activate the shut-off valve [8] until the spray line is depressurized.
2. Screw the cover [19] off the tank. (Fig. 6)
3. Dilute the remaining quantity twice in a row with 1/2 liter of water each time and spray
the resulting liquid onto the treated area.
Collect and dispose of the residual liquid according to all applicable laws, requi-
rements and regulations. Follow the instructions of the spray product
manufacturer!
4. Wipe off the device with a moist cloth.
5. For drying and storing the device, remove the cover and keep the device in a dry place
protected from sunlight and freezing temperatures.
Clean the protective equipment and yourself every time after usage.

Care and maintenance

Follow the instructions in the section entitled „Safety".
After using the device 50 times or if the device malfunctions, at least once a year, preferably
after the winter break:
1. Grease the diaphragm [24]. (Fig. 10)
2. Oil the pump rod [33]. (Fig. 20)
3. Grease the bearings on the shaft [16]. (Fig. 12)
4. Clean the nozzle [41] and the insert [40] under running water. If required use a brush.
(Fig. 18)
Observe the statutory accident prevention regulations in your country and check
the device at regular intervals. If there are no special regulations, we recommend
conducting a check every 2 years. We would be happy to provide you with an
inspection schedule in German or English.