INDOOR UNIT INSTALLATION

Correct orientation
of Installation Plate
1. Fit the Installation Plate
1.
Fit the installation plate
tion plate.
2.
If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall. Insert
Clip anchor
for appropriate mounting screws
3.
Fit the installation plate
NOTE
Fit the Installation Plate and drill holes in the wall according to the wall structure and
corresponding mounting points on the installation plate. (Dimensions are in "mm" unless
otherwise stated)
Over 12 cm from the wall
Left rear side refrigerant
pipe hole Ø
≥85
Indoor
4
50
Fig. 4
horizontally on structural parts of the wall with spaces around the installa-
on the wall with eight (8) type "A" screws
150 mm or more to ceiling
Indoor unit outline
A:780 (<4.6 kW model), 920 (≥4.6 kW model)
Fig. 5
Wall
Outdoor
≥5°
Fig. 6
.
.
Installation plate
Over 12 cm
from the wall
Right rear side
refrigerant pipe
hole ≥ 85