Settlement of outdoor unit
Anchor the outdoor unit with bolts, lock washers and nuts ø 10 mm or ø 8 mm tightly and horizontally on
a concrete or rigid mount.
Model
≤ 2.6 kW
2.6 kW < model ≤ 3.5 kW
3.5 kW < model ≤ 5.2 kW

Drain joint installation

(see fig. 12)
Fit the seal into the drain elbow, then insert the drain joint into the base pan hole in the bottom of the out-
door unit, rotate 90° to assemble them securely. Connect the drain joint with an extension drain hose (not
included). In this way condensed water, which is produced during heating mode of the airconditioner, can
be drained away.
Drain joint
Seal
A (mm)
B (mm)
458
290
549
266/276
530
290
Base pan hole of
outdoor unit
Seal
Drain pipe
Fig. 12
Air inlet
Air inlet
Air ourlet
Fig. 11