2.4 Adjustments
Summer/Winter Switchover
Press the button
(detail 9 - fig. 1) for 1 second.
The display activates the symbol Summer. The heating function is deactivated, whereas
the possible production of domestic hot water (with optional external hot water tank) re-
mains activated. The frost protection system remains activated.
To deactivate Summer mode, press the button
ond.
Thursday 9 Jan. 2014 11:33:03
fig. 11 - Summer
Heating temperature adjustment
Access the menu "Adjustment Temp" to vary the temperature from a minimum of 20°C
to a maximum of 80°C. Confirm with the OK button.
CH setpoint
80
to confirm
B
The boiler is sold with time program not activated. Therefore, if requested, this
is the setpoint value.
Heating temperature reduction
Access the menu "Reduction Adjustment Temp" to vary the temperature from a min-
imum of 0°C to a maximum of 50°. Confirm with the OK button.
CH setpoint reduction
35
to confirm
This parameter is used only if time programming is activated. See *** 'Time pro-
A
gramming' on page 85 ***
DHW temperature reduction adjustment (with optional hot water tank installed)
Access the menu "Adjustment Temp" to vary the temperature from a minimum of 10°C
to a maximum of 65°C. Confirm with the OK button.
CH setpoint
65
to confirm
B
The boiler is sold with time program not activated. Therefore, if requested, this
is the setpoint value.
(detail 9 - fig. 1) again for 1 sec-
23°C
32°C
fig. 12
fig. 13
fig. 14
cod. 3541F572 - Rev. 01 - 09/2015
DHW temperature reduction (with optional hot water tank installed)
Access the menu "Reduction Adjustment Temp" to vary the temperature from a min-
imum of 0°C to a maximum of 50°C. Confirm with the OK button.
DHW setpoint reduction
25
to confirm
This parameter is used only if time programming is activated. See *** 'Time pro-
A
gramming' on page 85 ***
Time programming
Programming the time is done in the same way both for heating and for DHW; the two
programs are independent.
To program Heating access the "Time Program" menu following the path "USER MENU
"HEATING"
"Time Program".
To program Domestic hot water (DHW) access the "Time Program" menu following the
path "USER MENU
"DOMESTIC HOT WATER"
Choose the desired type of programming and follow the instructions given below.
Select the day (fig. 16) or the interval of days to be programmed (fig. 17) and confirm with
the OK button.
Scheduler Set
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday-Sunday
to confirm
fig. 16
The program is weekly, which means that 6 independent time bands can be set for each
day of the week (fig. 18); 4 options can be selected for each time band:
ON. In case of a Heating/DHW demand, the boiler works at the set Heating/DHW
(fig. 12/fig. 14) Adjustment Temperature.
In case of a Heating/DHW demand, the boiler works at the Reduced Adjustment
Temperature. The Reduced temperature is obtained by subtracting the Reduction
Adjustment Temperature value (fig. 13/fig. 15) from the set Heating/DHW Adjust-
ment Temperature (fig. 12/fig. 14).
OFF. In case of a Heating/DHW demand, the boiler will not activate the Heating/
DHW mode.
-- : -- OFF. Time band disabled.
The boiler is sold with time program not activated. In fact, every day it will be
A
programmed from 00:00h to 24:00h in ON mode (fig. 18).
First, set the start time of the first time band (fig. 18) using the contextual buttons 1 and 2.
Scheduler Set
1.
00:00
- 24:00
--:-- - --:--
2.
--:-- - --:--
3.
4.
--:-- - --:--
5.
--:-- - --:--
6.
--:-- - --:--
Copy to the Next Day
Save & Exit
to confirm
fig. 15
"Time Program".
5
Scheduler Set
Wednesday
Thursday
Friday
Saturday
Sunday
Monday-Sunday
Monday-Friday
Saturday-Sunday
7
to confirm
fig. 17
1
2
fig. 18
EN