8.9

Switching off the automatic mode

➤ Switch off the automatic mode switch (if available).
or
➤ Switch on the ignition.
✓ The display shows:
8.10

Operating two generators in parallel (optional)

I
NOTE
The maximum allowed load for the parallel system is 4800 W.
Without the parallel cable or with a damaged parallel cable the
proper operation of the system is not guaranteed, especially in
terms of load sharing.
You can independently turn each generator on and off. If the load is more
than 2600 W, you can start both generators in parallel.
In case both generators are turned on:
Disconnect the load before switching off the system.
9

Cleaning the generator

A
NOTICE! Beware of damage
 Do not clean the generator with a high-pressure cleaner.
Exposure to water can damage the generator.
 Do not use sharp or hard objects or cleaning agents for clean-
ing as these may damage the generator.
 To clean the generator, use water with a gentle cleaning
agent. Never use petrol, diesel or solvents.
➤ Clean the generator with a damp cloth from time to time.
➤ Remove any dirt from the air vents in the generator at regular intervals.
Make sure you do not damage the grilles of the generator in the process.
EN
.
GEN OFF
Cleaning the generator
21