Tabla De Contenido; Introduction; Combination - Daikin CMSQ200A7W1B Manual De Instalación

Ocultar thumbs Ver también para CMSQ200A7W1B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 96
CMSQ200A7W1B
CMSQ250A7W1B
C
ONTENTS
1. Introduction ................................................................................1
1.1. Combination................................................................................. 1
1.2. Standard supplied accessories.................................................... 2
1.3. Optional accessories ................................................................... 2
1.4. Technical and Electrical specifications......................................... 2
2. Main components.......................................................................2
3. Selection of location ...................................................................2
4. Inspecting and handling the unit ................................................3
5. Unpacking and placing the unit ..................................................3
6. Refrigerant piping.......................................................................4
6.1. Installation tools ........................................................................... 4
6.2. Selection of piping material.......................................................... 4
6.3. Pipe connection ........................................................................... 5
6.4. Connecting the refrigerant piping................................................. 5
6.6. Example of connection ................................................................ 7
7. Leak test and vacuum drying .....................................................9
8. Field wiring .................................................................................9
8.1. Internal wiring - Parts table ....................................................... 10
8.2. Power circuit and cable requirements ........................................ 11
8.3. General cautions........................................................................ 11
8.4. System examples ...................................................................... 11
8.5. Leading power line and transmission line .................................. 12
8.6. Field line connection: transmission wiring.................................. 12
8.7. Field line connection: power wiring ............................................ 13
8.8. Wiring example for wiring inside unit ......................................... 14
9. Pipe insulation..........................................................................14
10. Checking of unit and installation conditions .............................14
11. Charging refrigerant .................................................................15
11.2. Precautions when adding R410A .............................................. 15
11.3. Stop valve operation procedure ................................................. 15
11.5. Additional refrigerant charge...................................................... 16
11.6. Checks after adding refrigerant ................................................. 17
12. Before operation.......................................................................17
12.1. Service precautions ................................................................... 17
12.2. Checks before initial start-up ..................................................... 18
12.3. Field setting ............................................................................... 18
12.4. Test operation ............................................................................ 20
13. Service mode operation ...........................................................21
14. Caution for refrigerant leaks.....................................................22
15. Disposal requirements .............................................................22
READ THIS MANUAL ATTENTIVELY BEFORE STARTING
UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN YOUR
FILES FOR FUTURE REFERENCE.
IMPROPER
INSTALLATION
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY
DESIGNED
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
DAIKIN EQUIPMENT IS DESIGNED FOR COMFORT
APPLICATIONS. FOR USE IN OTHER APPLICATIONS,
PLEASE CONTACT YOUR LOCAL DAIKIN DEALER.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DEALER FOR ADVICE AND
INFORMATION.
THIS AIR CONDITIONER COMES UNDER THE TERM
"APPLIANCES NOT ACCESSIBLE TO THE GENERAL
PUBLIC".
CMSQ200+250A7W1B
Air conditioning system
4PW47543-1
Air conditioning system
Page
OR
ATTACHMENT
OF
FOR
USE
WITH
THE
The refrigerant R410A requires strict cautions for keeping
the system clean, dry and tight.
Clean and dry
Foreign materials (including mineral oils such as
SUNISO oil or moisture) should be prevented from
getting mixed into the system.
Tight
R410A does not contain any chlorine, does not
destroy the ozone layer, and does not reduce the
earth's protection against harmful ultraviolet radiation.
R410A can contribute slightly to the greenhouse
effect if it is released. Therefore we should take
special attention to check the tightness of the
installation.
Read "6. Refrigerant piping" on page 4 carefully and follow
these procedures correctly.
Since design pressure is 4.0 MPa or 40 bar (for R407C
units: 3.3 MPa or 33 bar), pipes of larger wall thickness
may be required. The wall thickness of piping must be
carefully selected, refer to paragraph "6.2. Selection of
piping material" on page 4 for more details.
1.
I
NTRODUCTION
This installation manual concerns outdoor units of the Daikin
CMSQ-A7 series. These units are designed for outdoor installation
and used for heat pump applications.
The CMSQ-A7 units can be combined with Daikin indoor units for air
conditioning purposes, and suitable for R410A.
The present installation manual describes the procedures for
unpacking, installing and connecting the CMSQ-A7 units. Installation
of the indoor units is not described in this manual. Always refer to the
installation manual supplied with these units for their installation.
1.1.

Combination

The indoor units can be installed in the following range.
Always use appropriate indoor units compatible with R410A.
To learn which models of indoor units are compatible with
R410A, refer to the product catalogs.
Total capacity/quantity of indoor units
Total capacity
of indoor units
CMSQ200
CMSQ250
NOTE
The table above shows the possible total capacity
and number of possible indoor units when
configured in a standard combination.
Refer to the service manual for more details when
using a configuration other than a standard
combination.
Installation manual
Total quantity
of indoor units
100~200
2~4
125~250
2~4
Installation manual
1