2.3 Panel Mounting

1-Before mounting the device in your panel,
make sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the
mounting clamps are on the unit, put out them
before inserting the unit to the panel.
2.4 Removing from the Panel
2
3. Using Prokey
TO USE PROKEY, VALUE OF THE PrC PARAMETER MUST BE '0'.
IF PrC=1 AND
BUTTON IS PRESSED
DEVICE TURNS BACK TO THE MAIN OPERATION SCREEN OR YOU CAN PRESS SET
BUTTON TO TURN BACK TO MAIN OPERATION SCREEN.
DOWNLOADING FROM DEVICE TO PROKEY
1.The device is programmed by using the parameters.
2.Energize the device then put in PROKEY and press
display. When the loading has finished,
3.Press any button to turn back to main operation screen.
4.Remove the PROKEY.
NOTE:
message is shown when an error occurs while programming. If you want to reload, put
in PROKEY and press
device will turn back to main operation screen.
DOWNLOADING FROM PROKEY TO DEVICE
1.Switch off the device.
2.Put in PROKEY then energize the device.
3.When the device is energized, the parameter values in PROKEY, start downloading to the device
automatically. At first,
message is shown.
4.After 10 seconds device starts to operate with new parameter values.
5.Remove the PROKEY.
NOTE:
message is shown when an error occurs while programming. If you want to reload,
switch off the device and put in PROKEY then energize the device. If you want to quit remove
PROKEY and press
1
2
1-Pull mounting clamps from left and right fixing
sockets.
2-Pull the unit through the front side of the panel
1
MESSAGE WILL BE SHOWN. 10s. LATER
message is shown.
button. If you want to quit, remove PROKEY and press
message is shown on the display, when loading has finished,
button. The device will turn back to main operation screen.
3
3- Insert the mounting clamps to the fixing sockets
that located left and right sides of device and make
the unit completely immobile within the panel
Before starting to remove the unit from
c
panel, power off the unit and the related
system.
button.
Message is shown on the
3
button. The
5

Publicidad