2.2 Cable Recommendations to Connect the Sensors
Use shielded cables with wire gauge between 0.14 mm
(15 AWG). Connect the shield in the control ground plate. Refer to the SSW7000
user's manual for further details.
2.3 Insulation
The circuit connected to the sensors has a strong insulation from the other circuits
in the control board. But it's recommended that all the sensors be always isolated
from the live parts of the motor.
3. FIRST TIME START-UP
Step 1: After installed the module and connected its cables, energize the SSW7000
control board;
Step 2: Check if the module was correctly identified by the control: P0027 = 28xx
(IOE-04);
Step 3: Setup the parameters related with the used module according with the
application needs. Refer to the SSW7000 programming manual for further
details.
Temperature Transducer Module IOE-04
- English -
(26 AWG) and 1.5 mm
2
SSW7000 | 5
2