Contents
1 Safety Notes
.............................................................
2 Application
.................................................................
3 Technical Data
........................................................
.....................................................................
.........................................................
................................................................
1
Safety Notes
The regulator is installed into the boiler
facia. The regulator may only be con-
nected according to the wiring diagram.
Under no circumstances should the reg-
ulator be connected to the 230 V mains.
The regulator is to be used exclusively
in connection with a boiler equipped with
Bosch Heatronic control.
Before installing the regulator, the volt-
age supply (230 V, 50 Hz) to the boiler
must be disconnected.
2
Application
TA 211 E is a flow temperature regulator con-
trolled by outside temperature to be installed
into the facia of appliances, equipped with
Bosch Heatronic control.
2.1
Items Supplied
Included in the items supplied (Fig.
the TA 211 E is an outside temperature sen-
sor with mounting material.
2.2
Accessories
A mechanical flow temperature limiter must
be fitted to the flow pipe of underfloor heating
systems, in accordance with the manufactur-
er's instructions.
The TA 211 E is supplied without a time
switch. This is available as an accessory.
A remote control with a time switch can also
be used (not in UK, see the following table)
10
10
10
11
11
..........................................
12
........................................
12
..............................
15
........................
15
15
) with
2
The following combinations are permisable:
Combination
TA 211 E + DT 1
TA 211 E + DT 2
TA 211 E + TFQ 2 W
TA 211 E + TFP 3
* Not in UK.
Note:
According to Par. 7 of the Heating
System Regulations, the TA 211 E
can be operated only in conjunction
with a time switch.
3
Technical Data
Measuring range of the
outside temperature sensor - 20 ...+30 °C
Permissible ambient
temperature of the outside
temperature sensor
Protection class
3.1
Measured Values,
Outside Temperature Sensor AF
°C
V
AF
- 20
2392
2.64
- 16
2088
2.49
- 12
1811
2.33
- 8
1562
2.16
- 4
1342
1.99
0
1149
1.82
TA 211 E
Electrical Cir-
cuit Diagram
Fig.
8
Fig.
8
Fig.
8
Fig.
8
Fig.
9
Fig.
9
Fig.
9
Fig.
9
Fig.
10
Fig.
10
Fig.
10
- 30 ... +50 °C
III
°C
V
AF
4
984
1.65
8
842
1.49
12
720
1.34
16
616
1.20
20
528
1.07
24
454
0.95
10