Problem Identification - Master XL5 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15

10. PROBLEM IDENTIFICATION

PROBLEM
Generator
1. Generator blocked
doesn't run
2.The power switch is in the "OFF" (0)
position
3. No power
4. Feeder cable unplugged
5. Blocked control card
6. Wrong thermostat setting
7. Temperature sensor override
8. Fuse damaged
Motor/pump
1. No fuel
runs but the
fl ame does not
2. Ignition device is dirty
start
3. Fuel fi lter is dirty
4. Nozzle is dirty
5. Photocell is dirty, damaged or
installed improperly
6. Foreign substances present in the
tank
7. Electrodes are used up or placed at
an improper distance
Fan blocked or
1. Engine damaged
spins too slowly
POSSIBLE CAUSE
POSSIBLE SOLUTION
1. Restart the generator
2. Turn the switch "ON" (|)
3A. Plug the feeder cable properly into the
socket
3B. Check the power supply network
3C. Contact the technical service center
4. Contact the technical service center
5A. Restart the generator
5B. Identify the display error
5C. Contact the technical service center
6. Calibrate the thermostat by setting it
higher than ambient temperature
7A. Wait at least ten minutes then try to run
ignition again
7B. Contact the technical service center
8. Contact the technical service center
1. Turn off the generator, refi ll the fuel tank
then restart the generator
2. Contact the technical service center
3. Clean the fi lter using clean fuel
4. Contact the technical service center
5. Contact the technical service center
6. Empty and refi ll the fuel tank with clean
fuel
7. Contact the technical service center
1. Contact the technical service center
GB

Publicidad

Tabla de contenido
loading

Tabla de contenido