installation requirements
LOCATION REQUIREMENTS
Clearances and dimensions
For OTR over Gas Stove, please follow local GAS CODE.
BEFORE YOU BEGIN to install this appliance, refer to the following information,
dimensions, and clearances. Do not locate the range where it may be
subject to strong drafts. Provide adequate clearances between the range and
adjacent combustible surfaces. These dimensions must be met for safe use of
the range. The location of the electrical outlet and gas piping may be adjusted to
meet the following dimensions and clearances.
For installation in Canada, a free-standing range is not to be installed
closer than 4.7 in (12 cm) from any adjacent surface.
This range has been designed to comply with the maximum allowable
wood cabinet temperature of 194 °F (90 °C). Make sure the wall covering,
CAUTION
countertops, and cabinets around the range can withstand the heat (up to
194 °F [90 °C]) generated by the range. If not, discoloration, delamination, or
melting may occur.
Side
Clearance
Above
4 in
Cooking
(10.2 cm)
Surface to
Wall
24 in
(61 cm)
Lower
36 in
Cabinet
(91.4 cm)
Depth
30 in
30 in (76.2 cm)
6 in
18 in (45.7 cm)
(15.2 cm)
0 in (0 cm)
Clearance
Below
Cooking Top
and at Rear
and Sides of
Range
13 in (33 cm)
Overhead
Cabinet
Depth
installation requirements _21
0 in
(15.2 cm)