NOTICE
Note that the individual interfaces require different cable combinations
for commissioning.
CML 700i with IO-Link or analog interface
4
A Receiver (R)
B Transmitter (T)
C Connection cable (M12 socket, 8-pin)
D Synchronization cable (M12 plug/socket, 5-pin)
E PWR IN/OUT
Connect
Ä
Connect connection X2 to connection X3 using the appropriate synchroniza-
tion cable.
Ä
Connect connection X1 to the voltage supply and the control using the appro-
priate connection cable.
CML 700i with IO-Link interface
PIN X1 - Logic and power on the receiver
1
VIN: +24 V DC supply voltage
2
IO 1: input/output (configurable)
Factory settings: teach input (Teach In)
3
GND: ground (0 V)
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
Factory settings: Trigger input (Trigger In)
6
IO 3: input/output (configurable)
7
IO 4: input/output (configurable)
8
GND: ground (0 V)