EN
CML 700i with CANopen interface
PIN (X1) X1 - Logic and power on the receiver
X3 – Connection to transmitter
1
VIN: +24 V DC supply voltage
2
IO 1: input/output (configurable)
3
GND: ground (0 V)
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
6
RS 485 Tx-: synchronization
7
RS 485 Tx+: synchronization
8
SHD: FE functional earth, shield
PIN X1 - Short end of the Y-interconnection cable
X1 - Logic and power on the receiver
1
VIN: +24 V DC supply voltage
2
IO 1: input/output (configurable)
Factory settings: teach input
3
GND: ground (0 V)
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
Factory settings: trigger input
PIN X2 - CANopen interface
1
SHD: FE functional earth, shield
2
n.c.
3
CAN_GND: ground (0 V)
4
CAN_H:
5
CAN_L:
30
PIN (X3)
2
3
5
4
1