2.3 Installation niche features: Professional
Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2134 mm (84")
Minimum Niche Width
36": 902 mm (35 1/2")
24": 602 mm (23 3/4")
Door Swing Clearance
36": 1470 mm (57 7/8")
24": 1170 mm (46")
Door Opening Angle
105°
Width
36": 899 mm (35 3/8")
24": 599 mm (23 5/8")
Height
2120 mm (83 1/2") + 25 mm (1")
Depth with door
635 mm (25 ")
Minimum distance from the wall (hinge side)
36": 230 mm (9")
24": 160 mm (6 1/4")
IMPORTANT
If the units are to be installed inside a niche or within an
enclosed structure, it is necessary to design a ventilation
shaft at the back of the niche to assure proper ventilation
at the back of the unit.
Cross-sectional chimney ventilation area should equal
200cm² (31in²)
36: 230 (9")
24: 160 (6 ¼")
36: 899
(35 ⅝")
24: 599
(23 ⅝")
140 (5 ½")
140 (5 ½")
A
A
36: 902 (35 ½")
24: 602 (23 ¾")
635 (25")
560 (22")
693 (27 ¼")
min 50 (2")
EN