REGULATION OF THE EXTERNAL
SENSOR (fig. 25/a)
If an external sensor is installed, the value
of the output temperature is automatically
chosen by the system, which quickly adjusts
the environmental temperature on the
basis of the external temperature.
If you wish to change the value of the tem-
perature, increasing or decreasing that cal-
culated automatically by the electronic
card, proceed as indicated in the preceding
paragraph.
The level of various correction of a value of
temperature proportional calculated. The
display will be as shown in fig. 25/a.
TO SWITCH OFF THE BOILER (fig. 24)
In the case of a short absence, press the
key (
) of the controls (pos. 2).
The display will be as shown in the fig. 24. In
this way, leaving the electricity and the fuel
supply connected, the boiler is protected
from frost and from the pump becoming
blocked.
If the boiler is not used for a prolonged
period, it is advisable to disconnect the
electricity supply, by switching off the main
switch of the system, and to close the gas
tap and, if low temperatures are expected,
to completely empty the hydraulic circuits
to avoid pipes being broken by the forma-
tion of ice in the pipes.
ANOMALIES AND SOLUTIONS
When there is a functioning anomaly, the
display shows an alarm and the blue lumi-
nous bar becomes red.
Descriptions of the anomalies with the rela-
tive alarms and solutions are given below:
– ALARM 02 (fig. 27/a)
If the water pressure detected is lower
than 0.5 bar, the boiler will stop and the
display will show "ALL 02".
Lower the knob and turn it anti-clockwise
to open until the pressure indicated by
the display is between 1 and 1.5 bars.
If it is necessary to repeat the system
loading procedure, it is advisable to
contact qualified technical personnel
to check the seal of the heating system
(to check whether there are any leaks).
– ALL 03
Request assistance from qualified
technical personnel.
62
– ALL 05
Request assistance from qualified
technical personnel.
– ALL 06 (fig. 27/c)
Press the key
re-start the boiler.
If the anomaly persists, request assi-
stance from qualified technical person-
nel.
2
– ALL 07 (fig. 27/d)
Press the key
re-start the boiler.
If the anomaly persists, request assi-
stance from qualified technical person-
nel.
2
– From "ALL 08" to "ALL 10"
Request assistance from qualified
technical personnel.
Fig. 27/a
– ALL 13 (fig. 27/e)
Press the key
re-start the boiler.
If the anomaly persists, request assi-
stance from qualified technical person-
nel.
f the controls (2) to
– ALL 14 and ALL 15
Request assistance from qualified
technical personnel.
– "
Request assistance from qualified
technical personnel.
– From "ALL 20" to "ALL 29"
Request assistance from qualified
Fig. 27/c
technical personnel.
– From "ALL 30" to "ALL 35"
Request assistance from qualified
of the controls (2) to
technical personnel.
– ALL 70 and ALL 71
These alarms appear on the CR 73
remote control display. Request assi-
stance from qualified technical person-
nel.
GAS CONVERSION
If it is necessary to change to a different
type of gas, request assistance only from
authorised technical personnel.
MAINTENANCE
Annual maintenance of the appliance
should be planned sufficiently in advance,
requesting the assistance of authorised
technical personnel.
The boiler is supplied with an electric wire
for the electrical power supply which, in
Fig. 27/d
the case of replacement, must be substi-
tuted only by another obtained from the
constructor.
of the controls (2) to
2
Fig. 27/e
FLASHING"