automatic door to be operated manually.
DAY/NIGHT FUNCTION
The day/night function (connected to D/N contact) can be enabled when
required.
If option 0 is selected, the control is enabled and the INSIDE output
sensor only.
If option 1 is selected and the function is set to day (closed contact) the
following are enabled:
- Permanent release of electric lock
- OUTSIDE and INSIDE input and output sensor activation
- Opening if the door is closed in the event of a power failure (see CO-15,
option 1).
If the selector/switch connected to the D/N contact is set to night (open
contact) the OUTSIDE input sensor is disabled enabling exit only.
TIMED LOCK RELEASE
When the door is fitted with an electric lock, this may be released and
maintained released by means of the DAY/NIGHT function set to DAY.
If the DAY/NIGHT function is set to NIGHT, the electric lock is engaged
after the time selected on this function
TEMPORARY LOCK IF 2 SENSORS ARE ENGAGED
When both sensors are engaged, a temporary lock is activated (even if an
immobile object sensor is not installed). Option 0 disables the lock,
option 1 enables the lock.
OPENING WAIT TIME IN ENERGY SAVING MODE
When this function (CO-01, option 2) is selected, opening in energy
saving mode is activated only if the door remains closed for the minimum
time set on this function.
OPENING WIDTH 2 (MEDIUM)
Questa opzione determina la larghezza di apertura media (o anche detta
di risparmio energia) della porta selezionabile nella funzione di risparmio
energia (CO-01 opzione 2), nella funzione di 2 fermate (CO-01 opzione
3) e nella funzione con 3 fermate (CO-01 opzione 7).
Ricordate che l'apertura 2 media deve essere sempre inferiore
all'apertura 1 (CO-02). Se viene settata una distanza maggiore, questa non
viene registrata.
OPENING WIDTH 3 (MINIMUM)
This option sets door opening width in the 3-stop function mode (CO-01,
option 7).
Note that opening 3 must always be less than opening values 1 and 2;
values exceeding the latter will not be saved.
NOT USED
DECELERATION DISTANCE ON OPENING
This function enables the correction to max. 10% of the braking distance
CO-16
CO-17
CO-18
CO-19
CO-20
CO-21
CO-22
CO-23
in the opening direction set automatically when the door weight is
entered (CO-39). Following correction, if door movement jerks the
correction applied to the calculated value is incorrect.
DECELERATION DISTANCE ON CLOSING
This function enables the correction to max. 10% of the braking distance
in the closing direction set automatically when the door weight is entered
(CO-39). Following correction, if door movement is not smooth the
correction applied to the calculated value is incorrect.
BRAKING FORCE ON OPENING
When the door weight is entered, the braking force is set automatically.
Fine adjustment is possible by reducing the pre-set value by max. 10%. If
braking is smooth then settings are correct.
BRAKING FORCE ON CLOSING
When the door weight is entered, the braking force is set automatically.
Fine adjustment is possible by reducing the pre-set value by max. 10%. If
braking is smooth then settings are correct.
LOW SPEED OPENING DISTANCE
The low speed opening distance can be adjusted as required. When the
set value is not sufficient, the distance is extended automatically.
LOW SPEED CLOSING DISTANCE
The low speed closing distance can be adjusted as required. When the set
value is not sufficient, the distance is extended automatically
MOVEMENT AND POSITION INDICATOR
The output signal (available for a led, lamp, buzzer or other) is at 24 V dc
on connector CN2 (ORIGIN) on wires 3 (orange) and 4 (yellow). Option
0 enables the signal when the door is open, option 1 when the door is
closed, option 2 during opening and option 3 during closing.
PROTECTION PASSWORD
Do not touch this function; it is used exclusively for special applications
(e.g. military bases). In this case, contact us for the relative procedure.
WARNING: The following four functions regard impact force: CO-31
during high speed opening, CO-33 during low speed opening, CO-32
during high speed closing, CO-34 during low speed closing. Ensure that
all settings are correct to guarantee maximum door safety. A "less
sensitive" value could be better than a "sensitive" value during opening,
but is not recommended if impact is not detected. A highly sensitive value
should be set for closing, but an excessive value could cause reversal of
the motor in the case of windy conditions or small variations in friction.
IMPACT SENSITIVIT Y DURING HIGH SPEED OPENING
This function sets the sensitivity percentage following door impact against
an obstacle during high speed opening. Maximum sensitivity 10% -
minimum 200%. The buzzer sounds three times in the event of impact.
Pag. 39 di 56
CO-24
CO-25
CO-26
CO-27
CO-28
CO-29
CO-30
CO-31