IMPACT SENSITIVIT Y DURING HIGH SPEED CLOSING
This function sets the sensitivity percentage following door impact against
an obstacle during high speed closing. Maximum sensitivity 10% - 200%
minimum. (N.B. the buzzer does not sound on impact).
IMPACT SENSITIVIT Y DURING LOW SPEED OPENING
This function sets the sensitivity percentage following door impact against
an obstacle during low speed opening. Maximum sensitivity 10% - 100%
minimum. The buzzer sounds three times in the event of impact.
IMPACT SENSITIVIT Y DURING LOW SPEED CLOSING
This function sets the sensitivity percentage following door impact against
an obstacle during low speed closing. If the percentage entered is too
low, the door may not close. The buzzer does not sound on impact.
Maximum sensitivity 10% - minimum 100%.
In the event of difficulties during programming, the unit can be reset.
Select option 1 to cancel entered values and restore default settings as
shown in the "parameter selection" table.
DOOR SPEED WITH BATTERY OPERATION
(IN EVENT OF POWER FAILURE)
This function sets the door speed when powered by the back-up battery.
CO-32
CO-33
CO-34
CO-35
RESET
CO-36
MOTOR POWER
Factory default setting – DO NOT TOUCH. Refer to the value indicated in
W ( Watt) on the motor dataplate.
POWER DURING SELF-LEARNING
This function sets the motor power during the self-learning process. If
power is entered at 100% starting torque is increased; if entered at 10%
starting torque is reduced and may cause incorrect readings during self-
learning. The default settings are recommended
DOOR WEIGHT
The weight of the door must be entered in this function. The value (in kg)
determines the braking force and the deceleration distance which are
calculated automatically.
MECHANICAL LIMIT SWITCH POSITION LOCATING TIME
This function enables modification of the starting toque time on the
mechanical limit switch.
This time is required to locate the position of the limit switch and is used
only during the initial self-learning cycle when the unit is switched on.
The default settings do not normally require modification.
ELECTRIC LOCK SELECTION
This function enables selection of the type of electric lock (optional).
Option 0 controls an electric lock with release cable, option 1 controls an
electric lock with automatic release in the event of a power failure, and
option 2 disables operation of the electric lock.
CO-37
CO-38
CO-39
CO-40
CO-41