If dimension B is excessive:
• Use adjustable mounts (9014609 or 9014610) that allow setting the following four or eight values of Z (in cases where
you need to reduce or increase the value of Z):
P1: Z = 78 mm
P9: Z = 203 mm
P2: Z = 90 mm
P10: Z = 215 mm
P3: Z = 102 mm
P11: Z = 227 mm
P4: Z = 114 mm
P12: Z = 239 mm
P5: Z = 155 mm
P6: Z = 167 mm
P7: Z = 179 mm
P8: Z = 191 mm
Adjustable mount installation position
Left
Right
• Or move the gate hinges so as to reduce distance B (refer to "Specific Installations").
• Attach the mounting bracket P.
Drill and bolt the mounting bracket to the post.
Use a type of mounting that suits the post.
Mount direction
Left
Right
Note: Use the large circlips to attach the mounting bracket P.
Example
When the desired opening angle is 90°:
• Measure dimension X = 90 mm.
• Calculate dimension B = X + Z = 90 + 110 = 200 mm.
• Apply dimension B = 200 to the table and use a dimension A = 190 for a 90° opening.