Information Menu

The Information Menu displays valuable system and pool information. The AquaRite Pro will
default to displaying a portion of the Information Menu when no buttons have been pushed
for 2 minutes. The unit will automatically scroll through several status displays. To access all
of the Information Menu items, push the INFO button on the front panel. Advance through
the various menu items using the "<" or ">" buttons. A list of the Information Menu items is
shown below.
If ORP Auto Sensing is not used
Chlorinator
50 %
Super Chlorinate
22:15 remaining
The AquaRite Pro desired output % is shown here. If Super Chlorinate is
active, the display will show the time remaining until the AquaRite Pro will
return to the desired output %. This menu is disabled if an AQL-CHEM is
used and ORP Auto Sensing is enabled (see AQL-CHEM manual).
If AQL-CHEM is used
pH 7.5
(On)
ORP 700 mV
(On)
This display will be shown only if chemical sensing is enabled. This display
shows both pH and ORP levels/status when chemistry sensing is enabled
via the Chemistry Configuration Wizard (requires the use of AQL-CHEM
Sensing Kit). The AquaRite Pro will refer to these levels to determine how
much chlorine to generate (ORP) and how much acid to dispense (pH). Refer
to the AQL-CHEM manual for specific information about these levels as well
as the recommended ranges.
+23.45
+6.75A
29°C
3.2 g/L
+/- 23.45V is the voltage applied to the chlorinator cell
+/-6.75A is the current (amps) through the cell
29°C is the water temperature at the cell
3.2 g/L is the "instant" salt level at this time
For the chlorinator to be operating, several conditions must exist: the filter
pump must be running, the flow switch must be detecting flow, the chlorinator
setting must be set greater than 0%, the water temperature at the cell must
be between 12ºC and 60ºC, and the salt level must be within the operating
range. If any of these conditions are not met, the chlorinator diagnostic
display will tell you the reason. It's possible to have more than one reason,
in which case after you rectify what was displayed the first time, a second
display will appear.
If the current (amps) display is 0.00A, then the chlorinator is operating
normally but is in the off part of its normal operating cycle. Simply press
either the "+" or "-" key to start a new cycle.
7 / 20
No Function
Move to previous/next menu item
No Function
Move to previous/next menu item
No Function
Move to previous/next menu item
Press to switch chlorinator operation to opposite polarity (15 second delay)
Move to previous/next menu item
AquaRite Pro
Rev. C