Spare Parts - Hayward AQUA RITE pro Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
• ORP Probe Error -- If the CSM indicates that there is a problem with the ORP probe.
• ORP Low - Check Chlor -- If an ORP level of 350mV or less is detected. Check the chlo-
rinator for proper operation.
• ORP High - Check Chlor -- If an ORP level of 950mV or higher is detected. Check the
chlorinator for proper operation.
• ORP High - Chlor Off -- If an ORP level of 950mV or higher is detected and the chlorine
feed mode is ORP Auto Sensing, the chlorinator has been turned off. Check the chlorinator
for proper operation.
• ORP Timeout -Chlor Off -- If the unit has been chlorinating for more than the selected
sanitizer timeout without reaching the desired level, the chlorinator has been turned off. Press
the "+" button to reset the alarm and resume chlorination.
• Ambient Sensor -- If the internal (ambient) sensor is either open or short circuit.

Spare parts

5
Use Only Genuine Hayward
Replacement Parts
1
GLX-ARPRO-MEM-E
2
GLX-XFMR-E
3
GLX-R-10PK
4
GLX-PCB-ARPRO-E
19 / 20
4
3
1
5
6
T-CELL-3-E (60 m
6
T-CELL-9-E (95 m
6
T-CELL-15-E (150 m
7
8
GLX-FLO-RP
3
3
AquaRite Pro
2
7
GLX-CELL-UNIONE
)
8
GLX-UNION-ORING
)
9
GLX-CELL-PIPE
)
3
6
9
Rev. C

Publicidad

Tabla de contenido
loading

Tabla de contenido