LUCYB
17
See paragraph "7.3.5 NAKED in Slave mode" for the connection of 2 motors on opposite leaves.

3.6) Description of the electrical connections

The following is a brief description of the electrical connections; for
further information please read "7.3 Adding or Removing Devices"
paragraph.
FLASH: output for one or two "LUCYB" or similar type flashing
lights with single 12V maximum 21W bulb.
S.C.A.: "Open Gate Light" output. An indication lamp can be con-
nected (24V max. 4W). It can also be programmed for other func-
tions; see paragraph "7.2.3 Level two functions".
BLUEBUS: compatible devices can be connected up to this termi-
nal. They are connected in parallel using two conductors only,
through which both the electricity supply and the communication
signals travel. For more useful information about BlueBUS see also
Paragraph "7.3.1 BlueBUS".
STOP: input for the devices which block or eventually stop the
manoeuvre in progress. Contacts like "Normally Closed", "Normally
Open" or constant resistance devices can be connected up using
special procedures on the input. For more useful information about
STOP see also Paragraph "7.3.2 STOP Input".
S.C.A.
MOFB
16

OPEN CLOSE

STEP-BY-STEP: input for devices which control Step-by-Step
movement. It is possible to connect "Normally Open" devices up to
this input.
OPEN: input for devices which control only the opening move-
ment. It is possible to connect "Normally Open" devices up to this
input.
CLOSE: input for devices which control only the closing move-
ment. It is possible to connect "Normally Open" devices up to this
input.
AERIAL: connection input for the radio receiver aerial (the aerial is
incorporated in LUCY B).