7.3.6) Programming the direction of TEN installation
TEN leaves the factory programmed for a straight installation as shown in Figure 5. If installation requires TEN to be turned over, as shown
in Figure 7, the TEN control unit must be programmed as described in Table 22.
Table 22: Programming the direction of TEN installation
1.
Switch off TEN (for example by removing F2)
2.
Press and hold keys [Stop] and [Close]
3.
Switch on TEN
4.
Keeping [Stop] and [Close] pressed, wait for start-up of the control unit (approx. 4s);
5.
If leds P1, P2 and P3 are off , TEN is programmed for a straight installation as shown in Figure 5, if the
leds are lit, TEN is programmed for installation in an upturned position as shown in Figure 7;
6.
Keeping [Stop] and [Close] pressed, press and release [Open] (repeatedly if required). Leds P1,
P2 and P3 will illuminate or turn off with the following meaning:
ON = upturned installation (Figure 7)
OFF = straight installation (Figure 5)
7.
Release keys [Stop] and [Close]
Caution: If the upturned installation is programmed, during normal operation the keys Open and Close have the opposite functions to those
indicated on the control unit label.
7.4) Special functions

7.4.1) "Always open" function

The "always open" function is a feature of the control unit that enables continuous activation of an opening manoeuvre when the "Step-by-
step" command lasts more than 3 seconds; this can be useful for example to connect the SS terminal with the contact of a programme clock
to keep the gate open during a specific time band. This feature is valid regardless of the setting of the input SS (see "Function SS" in Table
16).
7.4.2) "Move Anyway" function
In the event that a safety device malfunctions or is out of service, the door may still be moved in "hold-to-run" mode. For details, refer to the
paragraph "Control with safety devices out of service" in the enclosure "Instructions and warnings for the TEN gearmotor user".
7.5) Connecting other devices
If external devices need to be powered, such as a proximity reader
for transponder badges or the lighting of a key-operated selector
switch, power can be supplied as shown in figure 39. The supply
voltage is 24Vac (-30% +50%) with maximum available current of
100mA.