tau D760M Guía Para La Instalación página 15

Panel de mandos para dos motores monofásicos 230v ac
Ocultar thumbs Ver también para D760M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
5 - 6 - 7
MOTOR M1
8 - 9 - 10
MOTOR M2
11 - 12
OPEN/CLOSE
11 - 13
PEDESTRIAN
11 - 14
STOP
SENSITIVE
15 - 18
EDGE
INTERNAL
16 - 18
PHOTOCELLS
EXTERNAL
17 - 18
PHOTOCELLS
19 - 20
ELECTRIC LOCK ELECTRIC LOCK power output 12 Vac max. 15 W;
21 - 22
2
RADIO CH
nd
GATE OPEN
23 - 24
WARNING LIGHT
25 - 27
PHOTOCELL TX
26 - 27
AUX
28 - 29
AERIAL
LOGIC ADJUSTMENTS
TRIMMER
second motor delay adjustment: during closing cycle from approx. 0 to 15 sec.; during
R. ANTA
opening from approx. 0 to 6 sec.
Motor 1 torque adjustment (swing 1). The trimmer is set to provide sufficient thrust
to work the gate without exceeding the limits established by current standards (EN
FR. M1
12453). Turning the trimmer clockwise (+) increases the motor torque, turning it anti-
clockwise (-) reduces it.
MOTOR M1 power output (opens the leaf fitted with the electric
lock), 230 Vac, max. 300 W. 5=CLOSE, 6=COMMON, 7=OPEN.
Notice: connect the capacitor between terminals 5 and 7;
MOTOR M2 power output, 230 Vac, max. 300 W.
8=CLOSE, 9=COMMON., 10=OPEN.
Notice: connect the capacitor between terminals 8 and 10;
OPEN/CLOSE button input (contact normally open); for operating
information see dip-switches 2 and 3 functions. (COMMON=11);
N.O. PEDESTRIAN button contact input – commands total opening
and closing of motor 1 – governed by dip-switches 2 and 3.
(COMMON=11);
STOP button input (normally closed contact); this stops the auto-
matic system. At the next command, the opposite operation to the
previous one is performed (COMMON=9);
SENSITIVE EDGE input (fixed edge, dip 10 OFF) or 8,2 KΩ RESIS-
TIVE SENSITIVE EDGE (dip 10 ON) - (normally closed contact);
Works only when the gate is opening; temporarily stops the gate
and partially closes it by about 20 cm in order to allow the obstacle
to be removed. (COMMON=18).
PHOTOCELL OR SAFETY DEVICE input INSIDE the gate (Nor-
mally Closed contact); COMMON=18.
When these devices trigger during the opening phase, they tem-
porarily stop the gate until the obstacle has been removed; during
the closing phase they stop the gate and then totally open it again.
PHOTOCELL OR SAFETY DEVICE input OUTSIDE the gate (Nor-
mally Closed contact); COMMON=18.
Then these devices trigger during the closing phase, they stop the
gate and then totally open it again.
Notice: Because the control of the safety system (FOTOTEST)
is performed on the photocell's transmitter, this must always
be powered by terminals 25 – 27, therefore if this connection is
broken the control unit will not accept any opening command.
To eliminate the safety system control, position dip-switch 6
to OFF.
2nd RADIO CHANNEL output; the output mode can be selected
through Dip Switches 7 - 8;
Warning: to connect other devices to the 2nd Radio Channel
(area lighting, pumps, etc.), use an additional auxiliary relay.
GATE OPEN WARNING LIGHT output; 24 V ac, max 3W; the light
lights with the same frequency as that of the flashing light for the
entire opening and closing manoeuvre and remains on if the gate is
open and off when the gate has closed;
24 Vac external transmitting photocell power supply output for safe-
ty device control (connect the external TX photocell only) max. of 2
photocell transmitters;
24Vac output, 10W for the power supply of photocells, external re-
ceivers, etc.
AERIAL input (EARTH=28, SIGNAL=29);
D760M
15

Publicidad

Tabla de contenido
loading

Tabla de contenido