tau D760M Guía Para La Instalación página 17

Panel de mandos para dos motores monofásicos 230v ac
Ocultar thumbs Ver también para D760M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Notice:
-
STOP input will stop the programming at any time. The programming mode remains active
and can be re-started from point 1
-
while DL7 blinks, press and hold down for at least 5 seconds P1 and P2 buttons to kill exit
programming mode
-
set a working time slightly longer than necessary (a couple of seconds) to allow complete
opening/closing of the leaves.
DIP SWITCH
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
3
NO REVERSE
4
DECELERATION
5
PRE-FLASHING
6
FOTOTEST
7 - 8
2nd RADIO CHANNEL operation (terminals no. 21 - 22)
Dip 7 Dip 8 Function
OFF
OFF
OFF
ON
OFF Monostable function active for 2 sec.: the radio control impulse causes the
ON
ON
ON
OPENING
9
RAM BLOW
SENSITIVE EDGE
10
SELECTION
JUMPER J1
Bridged=
following the connection of the external photocell contact (input 17 - 18), the gate
closes automatically after 5 seconds.
Not bridged=
function disconnected.
IMPORTANT:
Each pair of terminals attached to an NC contact that is not in use must be short-circuited in order to
ensure the proper operation of the board.
The door's earthing system must comply with current standards. The manufacturer will accept no li-
ability for any damage deriving from failure to comply with this requirement.
after opening, the gate automatically closes when the delay set on
On
the T.C.A. trimmer expires;
Off
automatic closing disabled;
with automatic closing enabled, a sequence of open/close com-
On
mands causes the gate to OPENCLOSE-OPEN-CLOSE etc (see
also dip switch 3);
in the same conditions, the same command sequence causes the
Off
gate to OPEN-STOP-CLOSE-STOP-OPEN-STOP (step-by-step);
the gate ignores the close command while it is opening (NO RE-
On
VERSE);
Off
the gate behaves according to the position of dip-switch n° 2;
the deceleration function is on (see "PROGRAMMING INSTRUC-
On
TIONS");
Off
the deceleration function is off;
On
the pre-flashing function enabled;
Off
the pre-flashing function disabled;
On
the "photocell test" function is enabled;
the "photocell test" function is disabled. N.B.: to be used when the
Off
photocells are not used;
Gate contact open: The contact activates on opening the gate and remains
active during the open time, during the TCA and during reclosure. It deactivates
once the gate has completed its closure movement.
Bistable function active: the radio control impulse causes the contact to activate
and remain active until the subsequent impulse.
contact to activate and remain active for 2 sec.
Monostable function active for 180 sec.: the radio control impulse causes the
contact to activate and remain active for 180 sec.
the "opening ram blow" function is on. This permits the release of
On
the electric lock (to be used only in the presence of an electric
lock);
Off
the "opening ram blow" function is off;
On
RESISTIVE SENSITIVE EDGE (terminal no. 15)
Off
RESISTIVE EDGE - fixed edge (terminal no. 15)
D760M
17

Publicidad

Tabla de contenido
loading

Tabla de contenido