WEG CFW500 Guía De Instalación, Configuración Y Operación página 9

Módulo plug-in de comunicación can
Ocultar thumbs Ver también para CFW500:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

An external power supply between pins 1 and 5
(figure
2) of the network connector is necessary.
Data for individual consumption and input voltage
are presented in
The indication of alarms, faults and communication
status is done through the HMI and product
parameters.
Connector
1
V-
2
CAN_L
3
Shield
4
CAN_H
5
V+
Figure 2: Connector pins for CAN interface
Table 2: Features of the power supply for CAN interface
Minimum
11
Typical
30
NOTE!
We recommend grounding the GND pin
of the CF W50 0 -CCAN Communication
Plug-in Module (pin 4 or 14).This grounding
is necessary for the cable shield to have a
connection to the ground wire.
CAN Communication Plug-in Module
table
2.
Negative pole of power supply
Signal of CAN_L communication
Cable shield
Signal of CAN_H communication
Positive pole of power supply
Power Suply (Vdc)
Maximum
30
Current (mA)
Description
Recommended
24
Maximum
50
CFW500 | 9