Mounting Instructions - Pahlen 300A Manual De Instrucciones

Ocultar thumbs Ver también para 300A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Pool lighting type 300
Type 300A - for casting in concrete pools with tile/mosaic covering
Consult your concrete/waterproofing supplier for any waterproofing and application method.

Mounting instructions:

NOTE! Minimum distance between stainless steel material and non-stainless (e.g. Concrete-reinforcing bars) will be 50 mm.
The front edge of the niche shall be in line with the concrete wall (see A in sketch below).
1. Attach and secure the niche to the pool frame with the cable outlet pointing upwards.
2. Apply some water-resistant grease in the threads of the niche.
3. Thread the cable conduit in the niche and in the junction box. The thread shall be sealed with e.g. thread tape.
The cable conduit shall be placed so that the bend radius is not below 100 mm.
4. Place the supplied spacer on the cable of the lamp where it runs through the cable gland of the niche.
Tighten the cable gland in the niche to seal the cable.
Insert the cable in the conduit and connect to the junction box.
Wrap excess cable behind the lamp and assemble the lighting unit in the niche.
5. Mount the front ring.
Concrete
Niche
Conduit
Concrete
Tile fix
Tile
Spacer
Lamp unit
Sealing ring
Tile fix
Tile
10
ENGLISH
Picture 1. The niche placed right.
Surface treatment
Designed by:
Drawn by: Date
E
ASA 2009-07-07
The tolerance class in accordance with this
Assembly drawing no.
Art.no.
part of ISO 2768-1
Scale
Nisch 300A BTGpool
monterad
Drawing number
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
Countersunk screw
M5x10 (6x)
Front Marine
Washer (6x)
Screw M5x50 (2x)
Approved by:
12252
Revised by: Date
1:3
Rev.no.
M11054 0

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

300ca

Tabla de contenido