Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage (External); Control Signals - Balluff BTL5-T1-M-P-S103 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL5-T1-M-P-S103 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL5-T1_ _-M_ _ _ _-P-S103
Micropulse Linear Transducer – Profile Housing
9

Technical Data

The following are typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Fully opera-
tional after power-up, with full accuracy after warm-up. Values are with BTL5-P-3800-2, BTL5-P-4500-1 or
BTL5-P-5500-2 magnet held at a constant offset from the transducer or with captive magnet BTL5-F/M/N-2814-1S
(see magnet section for exceptions):
Resolution, selectable
in steps of
Velocity, selectable
in steps of
Sampling rate f
= 1 kHz
Standard
Non-linearity
Hysteresis
Repeatability
(resolution + hysteresis)
Temperature coefficient
< (6 µm + 5 ppm * nominal length)/K
Shock loading
100 g/6 ms
per EN 60068-2-27
1
Vibration 12 g, 10 to 2000 Hz
1
per EN 60068-2-6
1
Individual specifications as per
Balluff factory standard
9.1
Dimensions, weights,
ambient conditions
Nominal length
< 4000 mm
➥ ➥ ➥ ➥ ➥ page 4
Dimensions
Weight
approx. 1.4 kg/m
Housing
anodized
aluminum
Housing attachment
Mounting clamps with isolation
bushings and screws
Operating temp.
–40 °C to +85 °C
Humidity < 90%, non-condensing
Protection class per IEC 60529
IP 67 when closed up
The following patents have been
granted in connection with this
product:
US Patent 5 923 164
Apparatus and Method for Auto-
matically Tuning the Gain of an
Amplifier
12
english
9.2

Supply voltage (external)

5 µm
Regulated supply voltage
BTL5-T1...
0.1 mm/s
Ripple
Current draw
Inrush
± 30 µm
Polarity reversal protection built-in
< 1 LSB
Overvoltage protection
< 2 LSB
Transzorb diodes
Electric strength
GND to housing
2
depending on load on VP
(repeater, bus terminator)
9.3

Control signals

RxD/TxD-N, RxD/TxD-P, Data GND
per EN 50170
9.4
Connection to the
processor
Cable
Twisted-pair, shielded.
Max. fieldbus length 1200 m
EU Directive
2004/108/EC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Elec-
tromagnetic Compatibility, has
confirmed that Balluff products
meet the EMC requirements of
the following Generic Standards:
EN 61000-6-1 (noise immunity)
EN 61000-6-2 (noise immunity)
EN 61000-6-4 (emission)
and the following product standard:
EN 61326-2-3
DC 20 to 28 V
< 0.5 V
ss
2
< 130 mA
< 3 A/0.5 ms
500 V DC
➥ ➥ ➥ ➥ ➥ Fig. 4-2
File No.
E227256
The CE Mark verifies
that our products meet
the requirements of
Emission tests:
RF Emission
EN 55016-2-3 (industrial area)
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4

Publicidad

Tabla de contenido
loading

Tabla de contenido