BTL PF _ 400- _ _ _ _ -C12NL _ _ -0-000S04
Magnetostrictive Linear Position Sensor – Profile Style
9

Technical data

The specifications are typical values for
BTL PF _ 400- _ _ _ _ -C12NL _ _ -0-000S04 with 24 V DC
and at room temperature and with a measuring length of
500 mm in conjunction with the magnet BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2,
BTL6-A-3801-2, BTL5-F-28141-S or BTL5-T-28141-S.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
9.1

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Typ. temperature coefficient
Shock rating as per
EN 60068-2-27
2), 3)
Continuous shock per
EN 60068-2-27
2), 3)
Vibration per EN 60068-2-6
Protection per IEC 60529 (when
threaded together)
9.2

Detection range/Measuring range

Measuring length
Resolution
Repeat accuracy
Length-dependent measuring
frequency
Measuring length ≤ 1270 mm
Measuring length > 1270 to
≤ 2650 mm
Measuring length > 2650 mm
Non-linearity
Detectable speed
16
english
−25...+85 °C
−40...+100 °C
≤ 90%,
non-condensing
≤ 30 ppm/K
1)
100 g/6 ms
50 g/2 ms
12 g, 10 ...2000 Hz
2), 3)
IP67
25...4000 mm
5 μm
≤ ±10 µm
1000 Hz
500 Hz
250 Hz
≤ ± 50 µm
≤ 10 m/s
9.3

Electrical data

Operating voltage U
b
Current draw (at 24 V DC)
Power consumption
Overvoltage protection
Voltage-proof up to (GND – Housing)
9.4

Electrical connection

Short circuit protection
Polarity reversal protected
9.5

Interface

IO-Link version
Transmission rate
Cycle Time
Data format
Error value
9.6

Materials

Housing material
Cover material
9.7

Mechanical features

Housing height
Weight (depends on length)
Measuring length 500 mm, magnet in the middle of the measuring range
1)
Individual specifications as per Balluff standard
2)
Resonant frequencies excluded
3)
18...30 V DC
≤ 60 mA
≤ 1.5 W
U
up to 36 V DC
b
500 V DC
Signal output to
GND and
30 V DC
U
up to 30 V DC
b
1.1
COM2 (38.4 kBaud),
COM3 (230.4 kBaud)
≥ 1 ms
32 Bit signed
0x7FFFFFFC
Aluminum
Zinc die cast, galvanized
20.8 mm
Approx. 1 kg/m