Mounting Instruction; Mounting The Hose; Connection Duct - Nederman 865 Serie Manual De Usuario

Ocultar thumbs Ver también para 865 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
EN
Exhaust Hose Reel
Item
Power supply
Power consumption
Protection class
Noise level
Material recycling
4

Mounting instruction

See pictures page 5. The maximum mounting height is depending of the hose length and
weight. NB! The maximum allowed uncoiled free hanging hose weight including nozzle is 30
kg. Choose such mounting height so that the hose in uncoiled position can be connected to the
vehicle's exhaust pipe without being stretched.
1.
Make sure that the surface, on which to mount the reel, is level. Drill 4 holes, using the hole
template which comes in the package.
2.
Fit the mounting brackets in such a way that will make the reel hanging horizontally. Ensure
that suitable fixing bolts are used considering the ceiling or wall construction material. The
bolts must each stand a tractive force of minimum 6500 N.
3.
Use approved lifting equipment to lift the reel. Fasten the reel in the brackets.
4.1

Mounting the hose

See pictures page 6. When the reel has been mounted and connected to the power suppy,
the hose should be fitted (concer-ning reels delivered without hose only). It should be noted
that the reel can not be rotated by hand.
1.
Fasten the hose with a hose clip on the connecting piece inside the drum.
2.
Aim the hand control towards the indicator (remote controled reel only). Press the UP-
button on the hand control. The indicator shows fixed red light. Release the button at
required hose position.
3.
Fit the nozzle.
4.
When needed adjust the limit positions for coiled and uncoiled hose (see page 9).
4.2

Connection duct

See pictures page 6. The connection hose supplied with the reel, should be used for
connecting the reel to duct systems and a central fan. NB! The duct must be fitted with hose
clips. Do not drill or fit with screws.
4.3
Fan positioning
A suitable fan can be selected from the Nederman fan range. To avoide leakage in the ducting
system the fan should be positioned outdoors or as near the duct outlet in the room as possible.
4.4
Electrical installation
See wiring diagram page 7.
All electrical work must be done by a qualified electrician according to local regulations.
Connect the reel to the power supply by joining the incoming cable to the connection block in
the reel's receiver.
10
Dimension
100 V, 115 V, 200 V, 230-240 V AC 1-phase, 50/60 Hz
Maximum 325 VA
IP 44
Measured according to ISO 11201. < 70 dB(A).
Reels without hose: 100 weight-%

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exhaust hose reel 865 serie

Tabla de contenido