Control Minor Organic Chlorine/Bromine (Version B): Inlet valve of water to tablets dispenser is too open or the load of tablets
inside the dispenser is too big. Therefore, we will have to close part of the inlet valve of water to the valve or reduce the load of
tablets inside.
On the contrary, if we are measuring and it is not possible to reach the programmed value it is a sign in:
Control Minor Inorganic Chlorine (VERSION A): Chlorine measuring pump has a percentage in the pump flow which is too low.
Therefore, we will have to increase that percentage.
Control Minor Organic Chlorine/Bromine (Version B): Inlet valve of water into the tablets dispenser is not open enough or the load
of tablets inside the dispenser is small. Therefore, we will have either to open the inlet valve of water a bit more or increase the load
of tablets inside.
17. FLOW DIAGRAM OF CONTROL MINOR PROGRAMMING
( displayof parameters)
p H : 7,8
SP : 7,2
m V : 800 SP : 760
ENTER
PROGRAMMING
[ SET P ]
ADJUST
ENTER
SELECT PARAMETER
[ pH ]
m V
ENTER
CORRECTOR
pH
[ MINUS ]
PLUS
ENTER
SET-POINT VALUE
p H :
7,2
ENTER
UPDATING DATA
MINOR ASTRALPOOL
(to the calibrations)
ENTER
PROGRAMMING
SET P
[ ADJUST ]
SELECT PARAMETER
p H
[ m V ]
ENTER
SET-POINT VALUE
m V :
750
ENTER
ESC
( fromcalibrations)
11
SELECT
PARAMETER
[ p H ]
mV
ENTER
IN SENSOR p H
7:00
PRESS
ENTER
ENTER
CAL p H : 7:02 / 0%
STABLE READING
PRESS
VAL
ELECTRODE STATUS
(ok pH 7)
CORRECT
INCORRECT
(ok pH4)
IN SENSOR p H
4:00
PRESS
ENTER
ENTER
CAL p H :
4:02 / 0%
Ref.16642R0100-gb-R04
SELECT
PARAMETER
p H
[ m V ]
ENTER
IN SENSOR m V
475
PRESS
ENTER
ENTER
CAL m V :
468 / 0%
VAL
(Flash reading)
UPDATING DATA
MINOR ASTRALPOOL
ESC
CALIBRATION
CANCELLED