Palazzetti MULTIFIRE NICOLAS Manual De Instalación, Uso Y Mantenimiento página 41

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.5.1 Discharge through roof using a traditional
chimney
be made in accordance with standards UNI 10683
- EN 1856-1-2 - EN 1857 - EN 1443 - EN 13384-
1-3 - EN 12391-1 both as regards the dimensions
and the construction materials used.
DAMAGED chimneys made from unsuitable
material (asbestos cement, galvanised steel,
etc.... with a rough and porous inside surface)
are prohibited by law and af
operation.
traditional chimney (Fig. 5.8) as long as the
following rules are observed:
-
check the conditions of the chimney; old
chimneys should be renovated by introducing
steel piping with suitable insulation (rock wool,
vermiculite).
the chimney only if the latter has a maximum
cross-section of 15 × 15 cm or diameter of 15
cm and features an inspection opening.
For larger chimneys, suitably insulated steel
pipes need to be inserted on the inside (diameter
according to the length (Fig. 5.9).
Makes sure connections to brick chimneys are
suitably sealed.
Avoid contact with combustible materials (e.g.
wooden beams) and in any case insulate these
available on the market.
1) Vermiculite and/or rock wool.
2) Steel pipes.
3) Closure panel.
cod. 004771980 - 09/2014 - Palazzetti - PN - Italy
INSTALLATION
fect proper stove
A) Chimney pot with wind protection
B) Maximum cross-section of 15 × 15 cm or diameter of
C) Seal
D) Inspection
15 cm and maximum height of 4- 5 metres
2
Fig. 5.8
1
3
Fig. 5.9
41/144

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Multifire ariaMultifire airMultifire aire

Tabla de contenido