Stanley SSCL180 Manual Del Usuario página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
Batteries and Power
Battery Installation / Removal
(See fi gure
)
B
Laser Tool
• Turn laser tool to bottom. Open battery compartment
cover by pressing locking tab and opening door.
• Install / Remove batteries. Orient batteries correctly
when placing into laser tool.
• Close and lock battery compartment cover by pushing in
until securely closed.
WARNING:
• Pay close attention to the battery holder's (+)
and (-) markings for proper battery insertion.
Batteries must be of same type and capacity. Do
not use a combination of batteries with different
capacities remaining.
Set Up and Operation
When using your laser tool always remember to utilize your
levelling legs and level vials.
NOTE:
• To achieve an accurate 90° laser cross the appropriate
levelling vials must be level. The laser emitting side of
rotating head needs to be perpendicular with your targeting
surface.
Level Adjustment
(See Figure
and
)
C
D
• Both bubbles should be centered in the vials
• If adjustment is required, proceed as follows:
• Turn the front adjustable legs to bring the fi rst bubble
vial to level.
• Level the second bubble vial by turning the rear
adjustable leg.
77-218
Calibration
Factory set and sealed for life
Specifi cations
Laser Tool
Horizontal / Vertical Accuracy
Vial Accuracy
Horizontal / Up Position
Down Position
Working Distance:
Laser Class:
Laser Wavelength
Operating Time:
Power Source:
Operating Temperature Range:
Storage Temperature Range:
SLP1 (77-218)
≤ .5 mm / 1 m
≤ 6.4 mm / 1 m
≤ 10.6 mm / 1 m
≥ 10 m
Class 1
(EN60825-1)
635 nm
≥ 16 hours
2 x "AA" Batteries
-10° C to +40° C
-25° C to +70° C
5

Publicidad

Tabla de contenido
loading

Tabla de contenido