4
Technical data
General data and operating conditions
4
Technical data
4.1
General data and operating conditions
Conformity and approval
Approval
UR
Mains data
Mains types
With grounded neutral (TT/TN systems)
IT systems
Protection of persons and equipment
Enclosure
Earth leakage current
Insulation resistance
42
UL508
Industrial Control Equipment, Underwriter
Laboratories (File-No. E219022) for USA and Canada
Operation permitted without restrictions
Max. mains voltage 400 V!
Observe instructions for special measures in the
documentation for the basic device!
EN 60529
IP20
NEMA 250
Protection against
contact to type 1
IEC/EN 61800-5-1 > 3.5 mA AC
> 10 mA DC
IEC/EN 61800-5-1 < 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Not in the wire range of the
terminals
Observe regulations and
safety instructions!
EDK94AZRP45 DE/EN/FR/ES/IT 5.0