5
Mechanical installation
Mounting grid
5.3
Mounting grid
Use with 9400
We recommend to provide the mounting plate with a grid pattern of M5
threaded holes for attaching the devices. This preparation enables easy
attachment of the devices, and the device sizes 1, 2, ... n can thus be mounted
directly adjacent to each other.
Fig. 5-3
Dimensions [mm]
Use with i700
For use in connection with the i700 series, fixing in the grid hole pattern is not
possible. The fixing holes are to be placed on the left next to the E70ACPS...
power supply module according to the dimensioned drawing.
50
Hole pattern for installation backplane (device sizes 1 to 3)
Hole pattern for other device sizes or filters mounted side-by-side or below (only
Single Drive)
Cable duct
SSP94NF311
EDK94AZRP45 DE/EN/FR/ES/IT 5.0