CN4 Connector for interlock
INT.0
Interlock 0
INT.I
Interlock 1
COM
common interlock
It is possible to enable the interlock.
In this case the door, once received the radar pulse, is opened only
if the input INT.I is not active, and activates the output INT.O during
the entire opening - stop - closing cycle.
The radar pulse received while the input INT.I is active is stored
and executed only when the input INT.I is deactivated.
If the interlock function is disabled, the input INT.I becomes a com-
Interlock function
CN6 Connector for commands and tests
TEST2
TEST1
CLOSE
OPEN
COM
Door 1
Monitored input TEST 2 (See point 4.9 monitored devices)
Monitored input TEST 1 (See point 4.9 monitored devices)
The OPEN and CLOSE have priority and determine the opening or
Input contact CLOSES
closing the door, which remains open/closed as long as the command
(Normally open)
is active.
During the opening or closing of the door executed via the OPEN/
CLOSE commands, the RAD INT, RAD EXT or START commands are
Input contact OPENS
ignored.
(Normally open)
A FOTO command sent during closing reopens the door immediately.
Common inputs
START
STOP
PHOTO
CLOSE
OPEN
RAD INT
RAD EXT
FOTO RALL
INTERLOCK
mand for the partial opening of the door.
Select the function Y=1 in the two control units when the doors must
alternate opening.
This function permits opening the second automatic door only when
the first automatic door is completely closed and vice versa, and is
used for classic insulated doors and safety reasons.