EN
6 - INSIGHTS - ADVANCED MENU
6.1 - Change parameters
Holding down the M button for at least 2 seconds until you hear a
beep displays and allows for editing of the following operating
parameters:
Function
Default
1.
650
2.
240
3.
25
4.
20
5.
8
6.
3
7.
200
8.
100
9.
10
A.
2
B.
75
C.
0
D.
0
E.
0
F.
0
G.
0
H.
1
J.
15
L.
0
N.
0
O.
0
P.
0
R.
0
T.
0
U.
0
Y.
0
To change a parameter, operate +and- then save holding down the OK button for at least 2 seconds until you hear a beep.
Holding down the M button for at least 2 seconds until you hear a beep shows the viewing mode again.
28
Min
Max
Value
100
700
Opening speed (mm/sec)
100
600
Closure speed (mm/sec)
1
30
Opening deceleration speed (mm/sec)
1
30
Closure deceleration speed (mm/sec)
2
50
Opening brake
2
50
Closing brake
50
300
Approach space at opening
50
300
Approach space at opening
1
100
Force on obstacle
1
60
Pause time (sec)
Percentage of partial opening run (1 to
50
99
100%)
0
15
Card Address (0 to 15)
0
1
Safety elastic
0
2
If door is forced (Pull & Go)
0
4
If there is power outage
If battery is dead
0
4
(can be displayed only if parameter P=1)
0
1
Direction of motion( )
0
59
Voltage applied when door stopped
0
2
FOTO Surveillance
0
2
FOTO RALL Surveillance
0
2
STOP Surveillance
0
1
Battery Test
0
1
Lock if R.INT or R.EXT
Sixth manual selector position
0
1
(LOGO KEY)
0
9
Duration opening START
0
1
Interlock
Please note: The function change from 1 to 9 involves the performingof
2 cycles of self-regulation during which the display shows "
0 = not present
1 = present
0=resistance to force
1 = opens
2 = stays open
0 = functioning continues
1=opens even if locked
2=closes and locks
3=opens only if unlocked
4=closes but does not lock
0 = functioning continues
1=opens even if locked
2=closes and locks
3=opens only if unlocked
4=closes but does not lock
0=right hand opening
1=left hand opening
N.B. Check hook dragging carts
mechanical part
0 = not monitored
1=one monitored device
2=two monitored devices
0 = not monitored
1=one monitored device
2=two monitored devices
0 = not monitored
1=one monitored device
2=two monitored devices
0 = test disabled
1 = test enabled
0 = Normal functioning
1= RINT or REXT closed door locks
0 = Partial opening
1=REXT(external radar active)
0 = step-step
1 to 9 (in tens of seconds)
0 = disabled
1 = enabled
"