CONNECTIONS DIAGRAM
INTERNAL RADAR
Sensor
Cable
connector
connector
EXTERNAL RADAR
Sensor
Cable
connector
connector
CN9 Connector for manual selector SMNPAE
+24V
Positive for powering selector
-24V
Negative for powering selector
A 485
Programmer connection EASY
B 485
Programmer connection EASY
Sel.R.
Manual selector
Reset H.
Reset
LED D.
Indicator LED error
OPT
Optional (not used)
1) - Without manual selector
If the manual selector is not desired, it is mandatory to set up a
bridge on the connector CN9 between the connection -24 and Reset
2) - With manual selector 2 wires
Connections with only 2 wires: LED error indication, reset hard-
ware, EASY terminal connection.
3) - With complete connections 8 wires
Recommended installation.
900PA025CT
HR100-CT
Descrip radar
Cable colours
Connections
Red
AC/DC 12 -~24V
Power
Black
AC/DC 12 -~24V
White
N.O.
Exit R2,3,4,5
Green
COM
Yellow
Collector
Exit R1,2
Blue
Transmitter
Grey
Test-P
Input test
Brown
Test-N
900PA025 CT
HR100-CT
Connections
Cable colours
Descrip radar
Red
AC/DC 12 -~24V
Power
AC/DC 12 -~24V
Black
White
N.O.
Exit R2,3,4,5
COM
Green
Yellow
Collector
Exit R1,2
Transmitter
Blue
Test-P
Grey
Input test
Test-N
Brown
900CT-PAE
EN