G. BOILER WATER MINIMUM LEVEL WARNING
When the machine is switched on (position 1 on the main switch) the boiler begins fi lling with water.
- IN THE CASE OF MACHINE START-UP: When the level sensor does not detect the presence of water
for longer than 6 seconds, it will disconnect the heating element and the machine will not heat; at the
same time, the display will show the alarm signal:
- IF THE MACHINE IS BEING WORKED WITH and the level sensor does not detect the presence of
water for longer than 3 seconds, it will disconnect the heating element and the machine will not heat.
To ELIMINATE this alarm the boiler water must be fi lled; the level sensor, on detecting water for more than 3 secons, will
clnnect the element and the machine will once more begin to heat.
2.9.3.2. TFT display screen (touchscreen)
Once the machine is on, the display screen will remain lit.
NOTE
Initially, if no customised image or text has been inserted, what we will see on the screen is the Iberital
logo. In the TECHNICAL MENU - Display confi g is an explanation of how we can customise the
display.
- ON position: When the main switch on the coff ee machine is activated and the display is in the ON
position (the screen shows Temp. Boiler | Time | Logo).
In order to set it to ON: when the display is in the OFF position, press the icon
- OFF position: When the main switch on the coff ee machine is activated and the display is in the OFF
position (the screen shows OFF | Time).
In order to set it to OFF: when the display is in the ON position, press the icon
The display screen during service, the normal operation of the machine, will vary based on the number
of groups on the model, whether or not it has a frother, and the type of services we have selected at any
given time.
NOTE
The display backlight brightness will dim after 5 minutes of inactivity, that is after the last change of status.
The display will return to standard brightness after a change: pressing the display itself, pressing any feed
button or due to machine programming.
INSTALLATION AND OPERATION MANUAL
Boiler
Empty
102ºC
13:34
13:34
OFF
IBERITAL
on the screen.
on the screen.
95