104
With soap water
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
After installation
Check whether the requirements listed in the table are met or whether there are any
malfunctions:
To check
Has the device been securely installed?
Would a refrigerant leak test be performed?
Have the lines been sufficiently insulated?
Is the water drained correctly?
Does the mains voltage of the socket
correspond to the voltage indicated on the
appliance's nameplate?
Have the electrical cables and lines been
installed correctly?
Has the appliance been properly earthed?
Does the power cord used meet the
manufacturer's requirements?
Are the air inlets and outlets blocked by
anything?
Have dust and dirt residues been removed
during installation?
Are the gas valve and liquid valve fully open?
Have the inlet and outlet of the pipe opening
been covered?
Possible malfunction
The unit may fall, wobble or make a noise
during start-up.
Insufficient cooling or heating capacity could
result.
Condensation and dripping water could result.
Condensation and dripping water could result.
Malfunctions may be caused or parts of the
unit may be damaged.
Malfunctions may be caused or parts of the
unit may be damaged.
This could result in electrical leakage.
Malfunctions could be caused or parts of the
device could be damaged.
Insufficient cooling or heating capacity could
result.
Malfunctions may be caused or parts of the
unit may be damaged.
Inadequate cooling or heating capacity could
result.
Inadequate cooling or heating capacity or
waste of energy could result.