Step 5: Connecting the Electrical System of the Outdoor Air Conditioner
1
Remove the wire clip; connect the power connection wire and signal control wire
(only for cooling and heating. Note: The terminal strip shown is for orientation
only. Refer to the actual terminal block.
2
Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note: After tightening the screws, gently pull the power cord to check that it is
properly tightened. Never cut the power cord to lengthen or shorten the cord.
Step 6: Neaten the Pipes
• The cables should be bent and
hidden as gently as possible and
run along the wall. Do not bend the
cables too much!
• If the outdoor air conditioner hangs
higher than the hole in the wall, you
must insert a U-shaped bend into
the pipe before it is led into the room
to prevent rainwater from entering
the room.
9K, 12 K
Indoor unit connection
U-shaped curve
Drain hose
18K, 24K
Indoor unit connection
Wall